- Rotary Frequency Converters
- Frequency Converter Basics
- Rotary Frequency Converters & Motor Generator Sets: Belt Coupled
- Rotary Frequency Converters & Motor Generator Sets : Direct Coupled
- Rotary Frequency Converters & Motor Generator Sets : Common Shaft
- Rotary Frequency Converters: Power Line Conditioners
- Solid State Frequency Converters – AC Power Sources
- Triathlon III Economical Frequency Converters
- Triathlon Precision AC Power Source - Adjustable Frequency Converter
- Triathlon Uninterruptible Power Supply System - UPS
- Brushless Permanent Magnet Generators & Alternators
- SERIES 30 - Brushless Permanent Magnet 400 Hz Generators - 150VA to 3 kVA
- SERIES 33 - Brushless Permanent Magnet 400 Hz Generators - 2.5 to 20 kVA
- SERIES 36 - Brushless Permanent Magnet 400 Hz Generators - .25 to 20 kVA
- SERIES 39 - Brushless Permanent Magnet 400 Hz Generators - 3 to 18.75 kVA
- Design Converter
- Frequency Conversion Guide
- World Power Guide (PDF)
- Refurbished and Surplus Equipment
- Downloads
- About Us
- Contact
- Home
|
|
Triathlon III Frequency Converter
3 Phase Input to 3 Phase Output Model (download PDF)
| MODEL | T3FC-33-500K | ||
|---|---|---|---|
| CAPACITY KVA | 500 KVA | ||
| INPUT | Voltage (select one individual voltage) |
3 Phase Delta 220/380/460 ± 20% 3 Phase Wye 190/200/208/220/230/240V ± 20% 3 Phase Wye 380/400/415/440/460/480V ± 20% |
|
| Frequency | 47 - 63 Hz (400 Hz. Optional) | ||
| Power Walk In | 0-100%: 20 seconds | ||
| OUTPUT | Voltage (select one individual voltage) |
3 Phase Delta 220/380/460V 3 Phase Wye 190/200/208/220/230/240V 3 Phase Wye 380/400/415/440/460/480V (± 15% adjustable from nominal) |
|
| Voltage Regulation | ± 1% from Set Point | ||
| Phase Shift (unbal. load) | < 0.5 Deg. | ||
| Frequency (select one) | 50 or 60Hz ± 0.1Hz (Optional: 400Hz.) (Optional: Switch Selectable 50/60Hz.) (Optional: Frequency Adjustable ±10% from nominal) |
||
| Power Factor | 0.8 | ||
| Distortion (THD) | <5.0% (Linear Load) | ||
| Crest Factor | 3:1 | ||
| Overload Capacity | 125% for 15 Minutes, 150% for 10 Minutes, > 150% for 1 Minute | ||
| Efficiency | >= 94% | ||
| INDICATORS | LCD | Real Time Status, Data or Historical Events, Parameters, Real Time Clock, Inverter & Buzzer | |
| LED | Up to date information (Status) to the User & Audible Alarm | ||
| PROTECTION | Over/Under Voltage | Alarm | |
| Output Short Circuit | Current Limited and cut-off, fuse and breaker | ||
| Overload | Auto-shutdown 1 Minute. Auto Restore when back to normal | ||
| Over Temperature | Auto-shutdown | ||
| Lightning / EMC Filter | MOV / Input & Output (FCC CLASS A) | ||
| EMI/EMC | EN50091-1, -2 Approved | ||
| Galvanic Isolation | Input & Output True Galvanic Isolation | ||
| INTERFACE | Contact Closure, RS-232/485 | Supports Remote Control Module, Optional SNMP card (Model No. MEGATEC Net Agent II) | |
| ENVIRONMENT | Operating Temperature | 0° – 40° C | |
| Humidity | 0 - 90% Non-condensing | ||
| Audible Noise | < 80 dB at 1 meter | ||
| DIMENSIONS | W x H x D (mm) | 3,380*1,800*1,000 | |
| W x H x D (in) | 133.1*70.9*39.4 | ||
| WEIGHT | Kilograms | ||
| Pounds | |||
| *Weights based on 220/380V IN and OUT. Weights may vary based on input/output frequency/voltage | |||

